产品技术资料 文献编号: 发布日期 数字荧光示波器
TDS3000C 系列以您承受得起的价格,提供了您需要的性能。100 MHz ~ 500 MHz 带宽,高达 5 GS/s 采样率,准确表示信号。41C-12482-26
-
手册 手册类型 部件号: 发布日期 TDS3000C Series
Digital Phosphor Oscilloscopes主要用户 077139700 TDS3000C 系列 用户手册
数字荧光示波器 User Manual用户 071231501 TDS3AAM
Advanced Analysis Application Module User Manual用户 071095301 TDS3TMT
Telecom Mask Test Application Module User Manual用户 071065502 TDS3LIM
Limit Test Application Module User Manual用户 071094101 TDS3VID
Extended Video Application Module User Manual用户 071034202 TDS3000C Series Installation and Safety Instructions
Oscilloscope Compliance and Safety用户 071357800 TDS3000C Series Service Manual
Digital Phosphor Oscilloscopes维修 071250702 TDS3000C Series Specifications and Performance Verification Manual
Digital Phosphor Oscilloscopes性能验证 071250802 TDS3000, TDS3000B & TDS3000C Series
Digital Phosphor Oscilloscopes Programmer Manual程序员 071038103 TDS3000C Series Declassification and Security Instructions
Digital Phosphor Oscilloscopes解密 077009100
-
技术文档 文档类型 发布日期 2016年测试测量解决方案
米乐m6网页版登录入口为您提供了三种中文版产品手册,向您介绍主要行业领域中的最新相关产品信息,即测试测量解决方案、视频产品选购指南和基础仪器指南。产品选择指南 示波器参考海报:基本特点和功能
本海报以视觉化方式呈现了示波器的基本特点与功能,包括有关捕获信号和高级触发。这张海报容易打印,提供了示波器的基本特点和功能,包括捕获信号及高级触发相关技巧。海报 采样解决方案概述
米乐m6网页版登录入口数字实时技术是一种透明的技术。由于它在重复性事件和单次事件上效果都非常好,因此不需要打开或关闭任何通道就能实现所标称的性能。DRT 用户可以享受模拟式的操作,同时获得数字示波器的精度和分析功能。屏幕更新速度极快,因为它在一次采集中就能捕获所有的波形样点。技术简介 示波器选型图
轻松选择示波器。操作指南 TDS3000C 调试技巧
本文档包括23页的“how - to”指令,如:调试数字定时问题调试上升时间和下降时间问题捕获难检毛刺和异常波形测试是否存在视频信号应用指南 米乐m6网页版登录入口DPO/MSO 系列和TDS/TPS 系列示波器
产品系列定位速查表: 米乐m6网页版登录入口DPO/MSO 系列和TDS/TPS 系列示波器速查资料 确保捕获完整图像
数字存储示波器对输入信号的取样速率越快,所显示波形的分辨率和细节的详细程度就越高。奈奎斯特取样理论表明取样速率至少应为被测信号中的最高期望频率的两倍。 然而,该理论仅适用于正弦信号。 现今的复杂波形无疑需要高于 2X 取样速率的数倍,才能精确捕获不断变化的事件或单次事件。应用指南 通过NI LabVIEW SignalExpress™ TE以及Tek tronix Instrumentation在线研讨会提高工作台生产力
米乐m6网页版登录入口和National Instruments利用易于使用的软件携手向您提供了用于简化信号采集、测试设置和分析的一些提示和工具。相关演示包括:USB即插即用连接、一次点击实现数据日志记录、实时分析和项目备案。应用指南 3 Series MDO vs TDS3000 Comparison Factsheet
More Capability and More Flexibility 3 Series MDO ✔ Unique hardware spectrum analyzer ✔ Optional integrated logic analyzer channels and function generator ✔ …速查资料 Working Remotely with Tektronix Oscilloscopes
There are several approaches you can take to work remotely with Tektronix oscilloscopes. The available techniques differ somewhat between instruments that run the Windows operating system and instruments that do not. This guide is designed to help …技术简介
-
软件 文档类型 部件号: 发布日期 TEKVISA Connectivity Software - V5.11.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …驱动程序 066093813 Tektronix Openchoice Desktop Application TDSPCS1 - V2.8
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …辅助功能 066093915 TEKVISA Connectivity Software - V4.2.0
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …驱动程序 066093812 CSharp Save HardCopy to PC_使用CSharp进行硬拷贝TDS,TBS系列示波器的屏幕
本例程提供了基本使用C#对TBS\TDS示波器进行控制,copy屏幕截图到PC上。 请注意相关软件配置环境以及VISA resource地址。Tektronix公司不负责该例程的完整性、可执行性和正确性。 请点击‘’安装说明“链接直接获取 TXT 源码文件脚本例程 MATLAB ICT send waveform to a reference channel on TDS2000_使用Matlab向TDS2000的Ref通达发送波形
演示了如何用Matlab对TDS2000进行编程并向ref通道发送波形数据。 请注意相关软件配置环境以及VISA resource地址。Tektronix公司不负责该例程的完整性、可执行性和正确性。 请点击‘’安装说明“链接直接获取 TXT 源码文件脚本例程 TDS3000 MATLAB ICT Get Screen 使用Matlab对TDS3000进行屏幕拷贝
演示了如何用Matlab对TDS3000进行屏幕拷贝。 请注意相关软件配置环境以及VISA resource地址。Tektronix公司不负责该例程的完整性、可执行性和正确性。 请点击‘’安装说明“链接直接获取 TXT 源码文件脚本例程 TEKVISA CONNECTIVITY SOFTWARE - V4.1.1
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol.When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …驱动程序 066093811 Tektronix Openchoice Desktop Application TDSPCS1 - v2.6
The Tektronix OpenChoice Desktop free application lets you capture oscilloscope screen images, waveform data, and settings from a Microsoft Windows computer. After installing the software, refer to the section “Connecting to a PC” in your …辅助功能 066093914 FIRMWARE UPGRADE FOR TDS3000C SERIES OSCILLOSCOPES - V4.31
The image for TDS3KC固件 063415807 Tektronix Toolbars for Microsoft Office 32 bit - V4.0.4
Tektronix Toolbars for Microsoft Office v4.0.4 provide toolbars (add-ins) for the 32 bit versions of Microsoft Excel and Microsoft Word. This version of Toolbars requires OpenChoice TekVISA v4.0.4 (Part Number 066093809) to be preinstalled on the PC …辅助功能 066133202 TEKVISA CONNECTIVITY SOFTWARE, V4.0.4
TekVISA is the Tektronix implementation of VISA (Virtual Instrument Software Architecture), an industry-standard communication protocol. When installed on a PC, TekVISA provides communication with instruments that are connected to the PC via various …驱动程序 066093809 FIRMWARE UPGRADE FOR TDS3KC SERIES OSCILLOSCOPES V4.26
FIRMWARE UPGRADE FOR TDS3KC SERIES OSCILLOSCOPES TO FIX THE ISSUE OF XSS IN E*SCOPE.固件 063415805 FIRMWARE UPGRADE FOR TDS3KC V4.25
FIRMWARE UPGRADE FOR TDS3KC SERIES OSCILLOSCOPES TO SUPPORT THE SEIKO DPU-S445 PRINTER.固件 063415804 NI SIGNALEXPRESS TEKTRONIX EDITION v2.5.1
National Instruments SignalExpress(tm) Tektronix Edition provides the industry's first true USB plug-n-play connectivity for instrumentation offering an intuitive drag-and-drop user interface that does not require any programming. SignalExpress(tm) …应用 066077003
-
常见问题 常见问题 ID 我的示波器使用什么机架安装?
示波器系列 机架安装 TDS1000/TDS2000 RM2000 TDS1000B/TDS2000B/TDS2000C RM2000B TPS2000/TPS2000B 无机架安装 - 皮带吊架 343-1689-00 TDS3000/TDS3000B/TDS3000C RM3000 DPO2000 RMD2000 …64571 如何手动操作将TDS3000C 数字荧光示波器上当前的波形以图片格式保存到U 盘
可以使用TDS3000数字荧光示波器的硬拷贝功能,具体操作如下: 点击操作按键“UTILITY”,打开“系统”菜单 操作屏幕下方的软键,在“系统”中选择“硬拷贝”,进入“硬拷贝”的设置菜单 选择“格式”,侧边栏出现对应的菜单,翻到最后一页(6 之6 页),将格式设置为PNG 或 *.img 格式即可 “接口文件”选择“文件”(指定到前端口存储设备) 余下的“选项”、“省墨模式”等,可以打开进入菜单设置,例如:直叶/横页?,压缩——否,省墨? 完成上述操作后,“MENU …473351 我应如何将我的TDS3000B系列的示波器连接到我的局域网上(LAN)?
以太网端口在示波器后面板的左上角.用一根以太网电线将 TDS 3000B系列连接到一个以太网端口或一个集线器( hub)上,然后开启示波器.当示波器完成开机过程后,按UTILITY(辅助功能)按钮. 在屏幕显示的下方菜单中按下System(系统)及选择I/O,然后选择Ethernet Network Settings(以太网网络设置). 从屏幕右方垂直排列的菜单中,选择自动获取 IP地址( DHCP/BOOTP "On"). 示波器将会采用 DHCP自动地由局域网中获取一个 IP地址. …65611 如何将我的色差分量模拟视频信号连接到具有TDS3VID或TDS3SDI视频模块TDS3000/B示波器上,来获得矢量视图的显示?
请参照以下链接指向的文件来查询有关连接的详情,并参照相关模块的用户手册来得到快速菜单设定的细节. TDS3VID Hookups(7Kb) TDS3SDI Hookups With Serial Digital Video (7Kb) TDS3SDI Hookups With Non-Serial Video(7Kb)65561 TDS3000/B,TDS3VID,TDS3SDI提供什么的视频测试功能?
以下是比较不同的视频测试功能在 TDS3000/B系列的示波器, 及选项TDS3VID,或TDS3SDI模块.型号/选项:TDS 3XXX, TDS 3XXXBTDS 3VID (软件)TDS 3SDI (硬件) + (TDS 3VID软件) 输入/输出:模拟输入模拟输入数字输入/模拟输出 到TDS3XXX/B模拟输入 顯示模式: 图像NA混合,Y通道的Y Pb Pr或S-Video混合,Y通道的Y Pb Pr或S …66086 我正在使用在高级数学模块(TDS3AAM)中的自定义单位功能(Define Units function),可是所定义的单位没有出现在显示上. 为什么?
自定义单位功能只在你的数学表达单位结果中含有 ”?”才有效,如“m?”. 当此发生时,你所定义的单位将取代 ”?”,例如:如果PSI是你所定义的单位,m?将会变成mPSI.66156 如何下载并安装 NI LabVIEW SignalExpress Tektronix Edition 的 30 天试用版?
注意:米乐m6网页版登录入口不再提供 NI LabVIEW SignalExpress Tektronix Edition。此常见问题部分“仅限用于历史记录”。 National Instruments SignalExpressTektronix Edition 是一款测量自动化工具,允许 SignalExpress 控制米乐m6网页版登录入口示波器、函数发生器、数字万用表或频率计数器并进行连续自动测量。 要使用 SignalExpress,必须先下载试用版,然后在购买 SignalExpress …66221 如何使用仪器的程序员手册?
TekVISA 下载链接: TEKVISA CONNECTIVITY SOFTWARE 您好,欢迎使用米乐m6网页版登录入口产品,今天我将介绍包含 3 个部分 TekVISA 使用指南系列的最后一个部分。我将概述程序员手册,以及如何使用它们来找到使用编程命令的正确方法。 每台示波器都附带一本程序员手册,其中包含所有可用于以编程方式控制仪器的命令。可在我们的网站 www.tek.com 上找到程序员手册。为了查找适用于我一直在使用的 MDO4104-6 的手册,我将进入我们的网站,然后在搜索栏中输入 …69186 如何使用 TekVISA 向我的仪器发送命令?
TekVISA 下载链接: /node/69201 为与示波器进行通信并控制示波器,可以使用 OpenChoice Talker-Listener。返回“应用程序和实用工具”面板,单击OpenChoice Talker Listener,然后单击”启动应用程序或实用工具”。系统会弹出一个新窗口,您将在此窗口中看到 4 个不同的面板:“仪器”,选择您想要与之通信的仪器;“输入命令或脚本”,输入编程命令并将其发送到仪器的字段 …69181 TekVISA是什么?我如何使用它来与我的仪器进行通信并控制仪器?
VISA 是 Virtual Instrument Software Architecture(虚拟仪器软件体系结构)的缩写形式。简言之,VISA 可处理您的计算机操作系统与仪器之间的通信。 您可能已熟悉 TekVISA。TekVISA 是米乐m6网页版登录入口自己的 VISA 品牌。安捷伦和 National Instruments 也有自己的 VISA。每个 VISA 中包含通信驱动程序、USBTMC 驱动程序(USB 测试和测量类驱动程序)、VISA 软件库和文档、仪器连接管理器 …69176 Can the P6139B be used on scopes that shipped with a P6139A? What is the difference between the P6139A and the P6139B?
From a specifications perspective, the probes are identical. Both are 500 MHz, 10X passive probes. The P6139B can be used on oscilloscopes that shipped with the P6139A. From a mechanical perspective, there are some differences: - Sharper tip …58111 Can I convert my wfm files to an open format+ such as a CSV (comma separated values) file?
You can use one of the following three WFM to ASCII converters. Converter for TDSxxx - works with files created by TDSx00 series (for example, TDS500 series) Converter for TDS5xxx,TDS6xxx, TDS7xxx, DPO7xxx,DPO70xxx, DSA70xxx Converter for the …56386 Which record length selection is best to use?
10K record length is best for signals characterized by: Large amount of horizontal detail Stable or slow changing Single shot 500 point or Fast Trigger is best for signals with: Higher trigger repetition rate …61421 What flash drives or USB sticks will work with my TDS3000C?
While Tektronix is not able to test all USB memory devices with all Tektronix products here is a listing of flashdrives that have been tested with the TDS3000Cs.60011 What Video test capabilities does the TDS3000/B/C+ TDS3VID+ TDS3SDI offer?
The following comparison shows the different video test capabilities of the standard TDS3000/B series Oscilloscopes, and optional TDS3VID, or TDS3SDI modules.Model / Option:TDS 3XXX, TDS 3XXXBTDS 3VID (Software) TDS 3SDI (Hardware) + (TDS 3VID …53661 What is the TekProbe interface?
In addition to coupling the signal from the probe to the oscilloscope the TekProbe interface provides power and offset to active probes. It also allows the oscilloscope to sense the probe's attenuation factor and/or probe type such as a 100X probe or …58876 I have a TDS3000 scope and just connected it to the Ethernet. In the Ethernet setup menu there is a Test Connection selection. What does the Test Connection test?
The Test Connection button pings the Gateway. If the Gateway IP Address is not specified, or specified incorrectly, the Test Connection will fail. This applies whether you are using a crossover cable or a "real" Ethernet connection. The selection is …55806 I purchased TDS3000/B/C series oscilloscope without any communication module. Now+ can I add a GPIB module onto my current TDS3014B? Is TDS3GV the right accessory?
The TDS3GV is the correct item to add GPIB. TDS3GV includes: GPIB, RS232, VGA interfaces and OpenChoice PC Communications software.58416 I cannot see my signal on the Oscilloscope. What can I do?
You have many options to help diagnose this issue, below are a few suggestions to get started. If you find yourself needing more help, please connect with our Technical Support Center. You can get started by pressing the "Contact Us" button on the …63686 Is it possible to use an oscilloscope to time NTSC black Burst and HD tri-level sync?
See document at left.58481 I have captured waveform data as .isf files. I want to know which software can convert .isf to .png or .jpg.
If the .isf file was captured on the DPO2000/MSO2000, DPO3000/MSO3000, DPO4000/MSO4000 series scope, you could open it with OpenChoice Desktop software. Or you could recall the waveform into the scope as a reference waveform, and then save on the …61871 Is it safe to operate the TDS3000 without connecting it to ground?
Yes, the TDS3000 can be safely floated to 30V RMS, while running on battery power. To make floating measurements on higher voltages a high voltage differential probe is recommended.60896 I downloaded and Installed OpenChoice Desktop, but it doesn't recognize my scope.
Refer to the Prerequisites.txt file available to download on the same page for OpenChoice desktop. Make sure you have all the prerequisites specified. Prerequisites 1. PC equipped with Microsoft Windows 7 32 Bit and 64 Bit OS, Windows 8.1 32 Bit …474266 I saved some oscilloscope .wfm and .isf files+ how do I view them on my pc?
The .isf and .wfm is the internal file format. It is designed first and foremost to be easily used by the oscilloscope. Most .wfm files (as well as many other waveform file formats) can be opened with TekScope. You can then save the file as another …59571 How do I connect my TDS3000B/TDS3000C Series oscilloscope to a network printer?
First be sure the oscilloscope is on the LAN, then go to the oscilloscope's Utility/System/Hardcopy menu and select the Format appropriate to your network printer (For example the Lexmark Optra Lxi is a postscript printer, so a user of that printer …60686 How can I change the TekVISA Instrument descriptor “device name” used to identify the oscilloscopes to which I routinely connect?
Open TekVISA V4.0.0+ OpenChoice Instrument Manager by selecting Start -> All Programs -> TekVISA -> OpenChoice Instrument Manager.Select (highlight) the Instrument descriptor listed in the Instruments list for the connected Oscilloscope.Click the …66181 How do connect my Color Difference Component Analog Video signals to the TDS3000/B Scope with TDS3VID or TDS3SDI Video module to get a Vectorscope display?
Please refer to the Hook-up document links below for connection descriptions, and to the Module User Manuals for Quick Menu setup details. TDS3VID Hookups (7Kb) TDS3SDI Hookups With Serial Digital Video (7Kb) TDS3SDI Hookups With Non-Serial …58251 How do I connect my TDS3000B series oscilloscope to my LAN?
The Ethernet port is located on the rear panel of the scope in the upper left rear corner. Connect the TDS3000B series to a Ethernet port or to a hub with an Ethernet cable and power the scope up. When the scope completes it's bootup, Press …60681 For the TDS5000 and TDS5000B scope+ along with the TDS3000 and TDS30000B series scopes+ the video trigger is for 720P/60. How can it be used for 720P/50 format?
For the TDS3000 series, you must have the TDS3VID to do HDTV triggering. For all of these scopes, setting the trigger to 720/60 will allow the scope to properly trigger on the 50 Hz rate as well as the 60/59.94 rates.57256 On the TDS3000C scopes+ can the USB port be used for remote control?
No. This port is only used for data storage to a memory stick.61026 My scope and PC are connected to a LAN. How can I establish a peer to peer connection to my PC via the scope's Ethernet port.
Certainly. A crossover cable or Ethernet Hub can be used to make a direct Peer-to-Peer connection from the scope's Ethernet port to the PC's Ethernet port. The concept is similar to using a null modem cable to connect a scope to a PC via RS-232. A …61916 I am trying to use RS232 communication to my scope and it is not working. What can I do to fix it?
The following is a trouble shooting guide which goes through the possible issues and how to fix them. Getting Started If you’re having communications problems between your PC and Oscilloscope this document provides the steps to help you get the …56651 What probe interface does my oscilloscope have?
Oscilloscope series Probe interface CSA7000/CSA7000B TekConnect DPO2000 TekVPI DPO3000 …64251 What are the differences between the TDS3000, TDS3000B and TDS3000C series oscilloscope?
There are several added functions and specs from TDS3000 to TDS3000B series as detailed below: Added WaveAlert............waveform anomaly detection Added E*Scope..............web based remote control Ethernet port is now standard Added an …58631 Is the WaveStar software Compatible with Win 7?
WaveStar is compatible with Win 7. Please refer to the attached doc for further details.69501 Where can I find an IVI driver for TDS200+ TDS1000/TDS2000+ TDS1000B/TDS2000B+ TDS2000C+ TPS2000+ TDS3000/TDS3000B/TDS3000C+ DPO2000/MSO2000+ DPO3000/MSO3000+ DPO4000/MSO4000 series?
IVI drivers to support LabView, LabWindows/CVI, and LabView SignalExpress can be found on the National Instruments Developer Zone, http://zone.ni.com/.For MSO3000 series please use the drivers posted for the DPO3000 series.For MSO4000 series please …60176 Are LabView drivers available for the TDS3000 series scopes?
Drivers for the TDS3000 series oscilloscopes can be found on the National Instruments web site, at the following link:TDS3000 Series Drivers and search with the scope model number.58036 How can I obtain the Open Choice Desktop software?
This [embed-software_word:0660939] is available for a free download from the Tektronix web site.This software also be available on some CDs that are shipped with some of our TDS or DPO/MSO oscilloscopes; however, may be an earlier version. If so …58236 How do I connect to my Oscilloscope via an Ethernet connection with NI-VISA?
Connecting via NIVISA has the same end effect to connecting to your instrument via TekVISA, but the method is different. Here is a step-by-step tutorial, using a TDS3000B connected through Ethernet, and NIVISA version 4.0.2. 1. Open National …63526 How do I utilize the measurement features on a TDS3000C series oscilloscope?
There are many features and fuctionalities that come with making measurements on the TDS3000C and older model scopes. Many of these inlcude "gating" your measurements to a certain part of your waveform or the full screen or between cursors. Sometimes …64676 How to save an image on the TDS3000C series scope?
Setup: First, select the Utility button, then select the System button from the menu below the display. Toggle the System button and highlight Hard Copy, select Format from the same lower menu. In the Format menu select BMP, PCX or TIFF. From the …60731 What communication modules can I use with my oscilloscope?
Please go to the "Supported Data Interfaces" section of www.tek.com/products/oscilloscopes/supported_printers.pdf.64051 Why do I get a flat line signal in Vectorscope Display Mode when I apply a 75% or 100% Color Bar Composite Video signal to Channel 1 of my TDS3000 series scope with TDS3VID or TDS3SDI Video module?
The TDS3VID, or TDS3SDI Vectorscope feature only supports Component Video signals. You must apply a Color Difference Component Analog Video signal, for example; Y,Pb,Pr to two input channels on the TDS3000/B Scope which uses XY mode to produce the …59016 When I plug in my TDS3EM module into my TDS3014B/C scope+ I get a message telling me there is a hardware conflict. Why is that?
The TDS3000B/C family already has an Ethernet connection built in. So when a TDS3EM module is installed there would be two ethernet (LAN) connections, which is not allowed.64271 Why does OpenChoice Desktop "Get Screen" operation time-out and display "Data transfer ended unexpectedly", when “Select Instrument”, “Get Data”, “Get & Send Settings” operations are successful?
When connecting to a TPS2000/B, TDS1000, TDS2000, or TDS3000/B series scopes with a Centronics parallel printer port using direct RS232, or RS232 to USB adapter, you must set the scope’s Printer Port to “RS232” (TDS1000/2000, TPS2000/B; Utility …64806 Why Should My Signal Fit Within The Screen Of My Tektronix Oscilloscope?
Scaling your signal to fit within the screen will remove signal distortion caused by clipping. Clipping is caused by exceeding the limits of the instrument's input. Tektronix's digital oscilloscopes are designed such that each division is 25 digital …60306 What cart does my scope use?
Below are the Instrument Carts that can be purchased from Tektronix. K4000 K420 K475 More information can …64561 What is the format of the .isf file?
The ISF format is the same as what the scope would send in response to the WAVFrm? command via an external program.The response to the WAVFrm? command is documented in the programmers manual for your instrument, which you can download from the …53511 What operating system does the TDS1000B+ TDS2000B+ TPS2000+ MSO/DPO2000+ TDS3000C+ MSO/DPO3000 and MSO/DPO4000 use? And are they susceptible to viruses?
The above oscilloscopes use closed embedded real-time operating systems and do not have the capability to create, modify, run or save programs that are on a USB device or LAN . Therefore, they are not susceptible to virus attacks and cannot spread …56996 What is the difference between the P6139A and the P6139B?
From a specifications perspective, the probes are identical. Both are 500 MHz, 10X passive probes. The P6139B can be used on oscilloscopes that shipped with the P6139A.From a mechanical perspective, there are some differences:- Sharper tip- Ground …64441 I am using the Define Units function in Advanced Math (TDS3AAM) and it is not showing up in the display. Why?
The Define Units function only takes effect when your Math Expression units result contain a “?”, such as “m?”. When this happens your Defined Unit will replace the “?”. i.e. m? would become mPSI if PSI was your defined unit.52831 Programing - How to get and plot a waveform from DPO/MSO/MDO4000 Series scope in Python
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …64796 Programing - How do I get a Screen Capture from DPO4000 scope using Python?
There are a few things that are needed for programming with an oscilloscope. First it's important to have a copy of your oscilloscopes Programmers manual. This can be found be searching for manuals on Tek.com and specifying Programmers manual in the …64791 What is the difference between Position and Offset on an oscilloscope?
To answer this first you need to understand the layout of how your waveform trace is displayed. On your oscilloscope you generally will see either 8 or 10 divisions vertically on the screen. Along the left side of the screen you will see a marker …247211 Does the ADA400A Differential Preamplifier work the TDS3000+TDS3000B+ and TDS3000C series of oscilloscopes?
Yes, the ADA400A will work with any oscilloscope that has the TekProbe interface. This includes the TDS3000 and TDS3000B families. The data sheet for the ADA400A was written before these products existed, so they were not mentioned.63381 My TDS3000B scope is set up to print to a network printer and every time I print I get a header page. How can I turn off the header page?
To turn the header page off consult your printer operation manual.56781 Can the TDS3BATC be used with (and charged in) a TDS3000 series (non B) scope+ even though the voltage is different than the TDS3BAT (14.4V vs 12V)?
TDS3BATB RECALLThe Lithium-Ion TDS3BATC will work with all TDS3000, TDS3000B, and TDS3000C scopes. However, unless the scope firmware is version 3.27 or greater, the battery charge information shown on the scope display will not be correct.58126 Can my oscilloscope operate on 400Hz power?
Most scopes have a wide range of operating voltages and frequencies, a full list can be found in the user manual of your specific oscilloscope. If you're having trouble finding your answer or can't find the manual, please call our Technical Support …63266