The Tektronix TIVM and TIVH Series IsoVu™ Measurement Systems offer galvanically isolated measurement solutions for accurately resolving high bandwidth, differential signals up to ±2500 V in the presence of large common mode voltages with the best in class common mode rejection performance across its bandwidth.
Features and benefits
- Bandwidths from DC to 1 GHz
- 100 Million to 1 (160 dB) Common Mode Rejection from DC up to 1 MHz
- 10,000 to 1 (80 dB) Common Mode Rejection at 1 GHz
- 60 kV peak Common Mode Voltage
- Up to ±2500 V Differential (DC + pk AC)
- Up to ±2500 V offset range
- Output clamping
- Safety certified
- DC and AC input coupling
Applications
- Half/Full Bridge designs using GaN, SiC, IGBTs
- Floating measurements
- Power Converter design
- Power Device evalsuation
- Switching Power Supply design
- Inverter design
- Motor Drive design
- Electronic Ballast design
- EMI
- ESD
- Current shunt measurements
- Remote probing capability
Product Description
The TIVM and TIVH Series (IsoVu) products can be used on most Tektronix oscilloscopes with the TekVPI interface and on MSO/DPO70K series oscilloscopes with the TCA-VPI50 adapter. IsoVu utilizes an electro-optic sensor that converts the electrical signal from the sensor tip cables to an optical signal, which electrically isolates the device-under-test from the oscilloscope. IsoVu incorporates four separate lasers, an optical sensor, five optical fibers, and sophisticated feedback and control techniques. The sensor head, which connects to the test point, has complete electrical isolation and is powered over one of the optical fibers (No batteries required). IsoVu is an ideal solution for users making the following measurements:
- Differential measurements in the following conditions:
- Complete galvanic isolation is required
- High common mode voltage
- High frequency common mode interference
- High frequency measurements
- Measurements in high EMI environments
- EMI compliance testing
- ESD testing
Specifications
All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.
- Overview
Characteristic TIVM1/TIVM1L TIVH08/TIVH08L TIVH05/TIVH05L TIVH02/TIVH02L Bandwidth/Rise time (Typical) 1 GHz / ≤ 350 ps 800 MHz / ≤ 435 ps 1 500 MHz / ≤ 700 ps 200 MHz / ≤ 1.8 ns Fiber cable length TIVM1: 3 m (9.8 ft)
TIVM1L: 10 m (32.8 ft)TIVH08: 3 m (9.8 ft)
TIVH08L: 10 m (32.8 ft)TIVH05: 3 m (9.8 ft)
TIVH05L: 10 m (32.8 ft)TIVH02: 3 m (9.8 ft)
TIVH02L: 10 m (32.8 ft)
1The 800 MHz bandwidth is achieved with the 50X and greater attenuation tips (MMCX50X, MMCX250X, SQPIN100X, SQPIN500X, WSQPIN1000X, or WSQPIN2500X).
- TIVM Series attenuation, Differential input voltage range, Offset range, Differential impedance (Typical)
- Use only the sensor tip cables listed below with the TIVM Series.
Sensor tip cable Attenuation Differential input voltage Offset range Input impedance 1X range 2X range SMA input 1X ±0.5 V ±1 V ±2 V 50 Ω || N.A. MMCX sensor tip cables IVTIP1X 1X ±0.5 V ±1 V ±2 V 50 Ω || N.A. IVTIP5X 5X ±2.5 V ±5 V ±10 V 250 Ω || <1 pF IVTIP10X 10X ±5 V ±10 V ±20 V 500 Ω || <1 pF IVTIP25X 25X ±12.5 V ±25 V ±50 V 1.25 kΩ || <1 pF IVTIP50X 50X ±25 V ±50 V ±100 V 2.5 kΩ || <1 pF
- TIVH Series attenuation, Differential input voltage range, Offset range, Differential impedance (Typical)
- Use only the sensor tip cables listed below with the TIVH Series.
Sensor tip cable Attenuation Differential input voltage Offset range Input impedance 1X range 2X range SMA input 1X ±0.5 V ±1 V ±25 V 1 MΩ || 20 pF MMCX sensor tip cables IVTIP1X 1X ±0.5 V ±1 V ±25 V 1 MΩ || 35 pF 1 MMCX10X 10X ±5 V ±10 V ±250 V 10 MΩ || 6 pF MMCX50X 50X ±25 V ±50 V ±250 V 10 MΩ || 3 pF MMCX250X 250X ±125 V ±250 V ±250 V 10 MΩ || 2 pF 0.100 in Pitch (2.54 mm) Square Pin sensor tip cables SQPIN100X 100X ±50 V ±100 V ±600 V 10 MΩ || 3.5 pF SQPIN500X 500X ±250 V ±500 V ±600 V 10 MΩ || 3.5 pF 0.200 in Pitch (5.08 mm) Square Pin sensor tip cables WSQPIN1000X 1000X ±500 V ±1000 V ±2500 V 40 MΩ || 3.5 pF WSQPIN2500X 2500X ±1250 V ±2500 V ±2500 V 40 MΩ || 3.5 pF
1With 6-inch tip cable sensor head 20 pF plus cable 15 pF.
- TIVM Series Common mode rejection ratio, sensor tip cables, and adapters (Typical)
Sensor tip cable/adapter DC 1 MHz 100 MHz 200 MHz 500 MHz 1 GHz MMCX Sensor tip cables IVTIP1X 160 dB 124 dB 120 dB 110 dB 100 dB 90 dB IVTIP5X 160 dB 124 dB 120 dB 110 dB 100 dB 90 dB IVTIP10X 160 dB 124 dB 120 dB 110 dB 100 dB 90 dB IVTIP25X 160 dB 120 dB 110 dB 100 dB 100 dB 90 dB IVTIP50X 160 dB 116 dB 100 dB 90 dB 90 dB 80 dB Adapters MMCX-to 0.1 in (2.54 mm) 160 dB 100 dB 70 dB 60 dB 40 dB 30 dB MMCX-to 0.062 in (1.57 mm) 160 dB 100 dB 70 dB 60 dB 40 dB 30 dB
- TIVH Series Common mode rejection ratio, sensor tip cables, and adapters (Typical)
Sensor tip cable/adapter DC 1 MHz 100 MHz 200 MHz 500 MHz 800 MHz MMCX Sensor tip cables IVTIP1X 160 dB 120 dB 120 dB 110 dB 110 dB 110 dB MMCX10X 160 dB 120 dB 110 dB 102 dB 91 dB 85 dB MMCX50X 160 dB 116 dB 100 dB 93 dB 85 dB 80 dB MMCX250X 160 dB 104 dB 85 dB 80 dB 73 dB 70 dB 0.100 in Pitch (2.54 mm) Square Pin sensor tip cables SQPIN100X 160 dB 110 dB 60 dB 50 dB 37 dB 30 dB SQPIN500X 160 dB 100 dB 70 dB 57 dB 39 dB 30 dB 0.200 in Pitch (5.08 mm) Square Pin sensor tip cables WSQPIN1000X 160 dB 100 dB 60 dB 47 dB 29 dB 20 dB WSQPIN2500X 160 dB 100 dB 60 dB 48 dB 33 dB 25 dB Adapters MMCX-to 0.1 in (2.54 mm) 160 dB 85 dB 70 dB 60 dB 40 dB 30 dB MMCX-to 0.062 in (1.57 mm) 160 dB 85 dB 70 dB 60 dB 40 dB 30 dB
- TIVM Series Maximum non-destructive voltage (Typical)
Sensor tip cable Vpk (DC + peak AC) VRMS Sensor head only 4.3 Vpk 3 VRMS IVTIP1X 4.3 Vpk 3 VRMS IVTIP5X 21.5 Vpk 12 VRMS IVTIP10X 43 Vpk 16 VRMS IVTIP25X 107.5 Vpk 25 VRMS IVTIP50X 200 Vpk 35 VRMS
- TIVH Series Maximum non-destructive voltage (Typical)
Sensor tip cable Vpk (DC + peak AC) 1 Sensor head only 25 Vpk IVTIP1X 25 Vpk MMCX10X 250 Vpk MMCX50X 250 Vpk MMCX250X 250 Vpk SQPIN100X 600 Vpk SQPIN500X 600 Vpk WSQPIN1000X 2500 Vpk WSQPIN2500X 2500 Vpk
1Derated with frequency; refer to the Maximum differential input voltage vs. frequency derating graph in the Specifications section of the TIVH Series IsoVu Measurement System User Manual.
- Common mode voltage
- 60 kV peak
- Common mode input impedance (Typical)
- Input resistance
- Galvanically isolated through the fiber optic connection
- Input capacitance1
- < 2 pF
1The capacitance between the sensor head and a reference plane. The sensor head is placed six inches (15.25 cm) above the reference plane.
- DC Gain accuracy1
- Differential DC gain accuracy in 1X range
- ±3% ± DC offset error voltage ± input offset accuracy error
- Differential DC gain accuracy in 2X range
- 60% of ± Full Scale: ±3% ± DC offset error voltage ± input offset accuracy error
>60% to 80% of ± Full Scale: 0% to –4% ± DC offset error voltage ± input offset accuracy error
>80% to 100% of ± Full Scale: 0% to –7% ± DC offset error voltage ± input offset accuracy error
1The difference between the measured DC gain and the nominal DC gain, divided by the nominal DC gain and expressed as a percent.
- System noise (input referred) (Typical)
Sensor tip cable/adapter 1X Range 2X Range TIVH08/TIVH08L Sensor head input SMA < 1.2 mVrms < 1.4 mVrms TIVH05/TIVH05L Sensor head input SMA < 0.72 mVrms < 0.85 mVrms TIVH02/TIVH02L Sensor head input SMA < 0.61 mVrms < 0.75 mVrms TIVM1/TIVM1L Sensor head input SMA < 0.8 mVrms < 1.6 mVrms Input referred noise with tip cable (Sensor head input SMA noise) * (Tip cable attenuation) (Sensor head input SMA noise) * (Tip cable attenuation) Examples: TIVH08 1X Range with MMCX10X tip cable: Noise = (1.2 mVrms) * (10) = 12 mVrms TIVH08 2X Range with MMCX10X tip cable: Noise = (1.4 mVrms) * (10) = 14 mVrms
- Propagation delay
- 3 meter fiber cable
- 35 ns ±5 ns
- 10 meter fiber cable
- 68 ns ±7 ns
- Laser certification
CLASS I LASER PRODUCT
This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007.
Ordering information
- TIVM models
- TIVM1
- Tektronix IsoVu 1 GHz Medium Voltage with 3 m cable
- TIVM1L
- Tektronix IsoVu 1 GHz Medium Voltage with 10 m cable
- TIVH models
- TIVH08
- Tektronix IsoVu 800 MHz High Voltage with 3 m cable
- TIVH08L
- Tektronix IsoVu 800 MHz High Voltage with 10 m cable
- TIVH05
- Tektronix IsoVu 500 MHz High Voltage with 3 m cable
- TIVH05L
- Tektronix IsoVu 500 MHz High Voltage with 10 m cable
- TIVH02
- Tektronix IsoVu 200 MHz High Voltage with 3 m cable
- TIVH02L
- Tektronix IsoVu 200 MHz High Voltage with 10 m cable
TIVM series
Standard accessories
- 016-2108-xx
- IsoVu product carrying case, soft case
- 016-2110-xx
- IsoVu accessories carrying case, soft case
- 003-1946-xx
- Solder aid for 0.062-inch (1.57 mm) pitch square pins (0.016 - 0.018-inch (0.4 - 0.46 mm) square pin installation tool)
- IVTIP5X
- 5X Sensor tip cable
- IVTIP25X
- 25X Sensor tip cable
- 003-1947-xx
- 5/16-inch SMA wrench/driver tool
- 131-9717-xx
- Probe tip adapter (blue), MMCX to 0.1-inch (2.54 mm) square pin (0.025-inch (0.635 mm) square pins)
- 131-9677-xx
- Probe tip adapter (white), MMCX to 0.062-inch (1.57 mm) square pin (0.016 - 0.018-inch (0.4 - 0.46 mm) square pins)
- 020-3169-xx
- DUT Interface pin kit with (qty. 20) 0.018-inch (0.46 mm) round solder-in pins
- 352-1171-xx
- Flexible tripods with quick release
- 344-0693-xx
- Flexible tripods feet, 3 each
- 352-1170-xx
- Probe tip tripods support with living hinge, 2 each
- 071-3495-xx
- User manual (English)
- ---
- Certificate of traceable calibration
Translated manuals can be downloaded as pdf files on your local Tektronix Web site.
Recommended accessories
- IVTIP1X
- 1X Sensor tip cable
- IVTIP10X
- 10X Sensor tip cable
- IVTIP50X
- 50X Sensor tip cable
TIVH series
Standard accessories
- 016-2108-xx
- IsoVu product carrying case, soft case
- 016-2110-xx
- IsoVu accessories carrying case, soft case
- MMCX50X
- 50X Sensor tip cable
- SQPIN500X
- 500X Sensor tip cable
- 003-1947-xx
- 5/16-inch SMA wrench/driver tool
- 131-9717-xx
- Probe tip adapter (blue), MMCX to 0.1-inch (2.54 mm) square pin (0.025-inch (0.635 mm) square pins)
- 352-1171-xx
- Flexible tripods with quick release
- 344-0693-xx
- Flexible tripods feet, 3 each
- 352-1170-xx
- Probe tip tripods support with living hinge, 2 each
- 071-3556-xx
- User manual (English)
- —
- Certificate of traceable calibration
Translated manuals can be downloaded as pdf files on your local Tektronix Web site.
Recommended accessories
- 003-1946-xx
- Solder aid for 0.062-inch (1.57 mm) pitch square pins (0.016 - 0.018-inch (0.4 - 0.46 mm) square pin installation tool)
- 131-9677-xx
- Probe tip adapter (white), MMCX to 0.062-inch (1.57 mm) square pin (0.016 - 0.018-inch (0.4 - 0.46 mm) square pins)
- 020-3169-xx
- DUT Interface pin kit with (qty. 20) 0.018-inch (0.46 mm) round solder-in pins
- IVTIP1X
- 1X Sensor tip cable
- MMCX10X
- 10X Sensor tip cable
- MMCX250X
- 250X Sensor tip cable
- SQPIN100X
- 100X Sensor tip cable
- WSQPIN1000X
- 1000X Sensor tip cable
- WSQPIN2500X
- 2500X Sensor tip cable
Supported oscilloscopes
The measurement systems can be used with the following Tektronix oscilloscopes. For oscilloscopes not included in this list, contact your local Tektronix representative.
- 5 Series MSO (WSQPIN2500X tip cables require V1.6 or later oscilloscope firmware)
- MDO3000 series (WSQPIN tip cables require V1.26 or later oscilloscope firmware)
- MDO4000C series (WSQPIN tip cables require V1.06 or later oscilloscope firmware)
- MSO/DPO/MDO4000B series (WSQPIN tip cables are not compatible)
- MSO/DPO5000B series
- DPO7000C series
In addition to the above oscilloscopes, the TIVH and TIVM measurement systems can also be used with the following oscilloscopes with a TCA-VPI50 adapter.
- MSO/DPO70000C series
- MSO/DPO70000DX series
- DPO70000SX series
Options
Service options
- Opt. C3
- Calibration Service 3 Years
- Opt. C5
- Calibration Service 5 Years
- Opt. D1
- Calibration Data Report
- Opt. D3
- Calibration Data Report 3 Years (with Opt. C3)
- Opt. D5
- Calibration Data Report 5 Years (with Opt. C5)
- Opt. G3
- Complete Care 3 Years (includes loaner, scheduled calibration, and more)
- Opt. R3
- Repair Service 3 Years (including warranty)
- Opt. R5
- Repair Service 5 Years (including warranty)
Probes and accessories are not covered by the oscilloscope warranty and Service Offerings. Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms.